Global : English
Items in Cart
0
 
Home » Products » Terminal Blocks & Connectors » Din Rail Terminal Blocks » CTS Series Screw Clamp Terminal Blocks » Multiple Level »

ODL2.5A(I.S)

Specifications Ratings as per Standards Extra Information Download PDF Email PDF Add To Cart Share
3dlogo
2.5 sq.mm 2 Level Offset internally shorted stackable type Terminal Block in Grey colour

ODL2.5A(I.S) internally shorted Terminal Block , the top level is offset from the bottom level by half the thickness of the terminal block. this creates better access for the bottom level screw while the wires are connected. It is recommended to use End Plates at both ends of the assembled ODL2.5A(I.S) sets for flat alignment to enable the effective use of end clamp. These are ideal for use in applications requiring high density wiring. Interconnection/shorting is possible with standard push in links.

TECHNICAL DATA
Rated Voltage 800 V
Rated Current 24 A
Tightening Torque 0.4 Nm
Housing MaterialPolyamide
Product FunctionDouble Level
Wire Entry Orientationside
Mounting PossibilityDIN 35/DIN 35-15 Rail
Operated byscrew driver
Rated Surge Voltage8 KV
Pollution Degree3
CONNECTION DATA
Conductor Cross Section Stranded min.0.2 mm²
Conductor Cross Section Stranded max.2.5 mm²
Conductor Cross Section AWG/Kcmil min24 AWG
Conductor Cross Section AWG/Kcmil max12 AWG
Conductor Cross Section Stranded with Ferrule/Lug min0.2 mm²
Conductor Cross Section Stranded with Ferrule/Lug max2.5 mm²
2 Conductors with same Cross Section Stranded min0.2 mm²
2 Conductor with same Cross Section Stranded max1.5 mm²
Conductor Cross Section Solid min0.2 mm²
Conductor Cross Section Solid max4 mm²
Stripping Length8 mm
DIMENSIONS
Height with DIN 35 x 15 mm rail 68.5 mm
Height with DIN 35 x 7.5 mm rail 61 mm
Length 62 mm
Width (Thickness)5 mm
ORDERING INFORMATION
CAT. NO.DESCRIPTIONSTD. PACK
ODL2.5A(I.S)2.5 sq.mm 2 Level Offset internally shorted stackable type Terminal Block in Grey colour50
ACCESSORIES
IMAGES
CAT. NO. DESCRIPTION STD. PACK
CA702
CA702 End Clamp in Polyamide 66 suitable for Din 32 / Din 35 / Din 35-15 Rails 50
CA202
CA202 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 25
CA509/K5
CA509/K5 Blank Marking Tag 100
SCS0.6/3.5AC
SCS0.6/3.5 Electricians Screwdriver for slotted screws 10
JX2.5/2
JX2.5/2 Shorting Link for 2.5 sq mm series 100
JX2.5/3 Shorting Link for 2.5 sq mm series 50
JX2.5/4 Shorting Link for 2.5 sq mm series 50
JX2.5/5 Shorting Link for 2.5 sq mm series 50
JX2.5/6 Shorting Link for 2.5 sq mm series 50
JX2.5/7 Shorting Link for 2.5 sq mm series 10
JX2.5/8 Shorting Link for 2.5 sq mm series 10
JX2.5/10 Shorting Link for 2.5 sq mm series 10
EP1ODL2.5
EP1ODL2.5 End Plate in Grey colour 50
EPODL2.5
EPODL2.5 End Plate in Grey colour 50
APPROVALS
  • Home » Products » Terminal Blocks & Connectors » Din Rail Terminal Blocks » CTS Series Screw Clamp Terminal Blocks » Multiple Level »
    Home » Products » Terminal Blocks & Connectors » Din Rail Terminal Blocks » CTS Series Screw Clamp Terminal Blocks » Multiple Level »
    ODL2.5A(I.S)
    Share
    
ODL2.5A(I.S)
    2.5 sq.mm 2 Level Offset internally shorted stackable type Terminal Block in Grey colour

    ODL2.5A(I.S) internally shorted Terminal Block , the top level is offset from the bottom level by half the thickness of the terminal block. this creates better access for the bottom level screw while the wires are connected. It is recommended to use End Plates at both ends of the assembled ODL2.5A(I.S) sets for flat alignment to enable the effective use of end clamp. These are ideal for use in applications requiring high density wiring. Interconnection/shorting is possible with standard push in links.

    TECHNICAL DATA

    TECHNICAL DATA
    Rated Voltage 800 V
    Rated Current 24 A
    Tightening Torque 0.4 Nm
    Housing MaterialPolyamide
    Product FunctionDouble Level
    Wire Entry Orientationside
    Mounting PossibilityDIN 35/DIN 35-15 Rail
    Operated byscrew driver
    Rated Surge Voltage8 KV
    Pollution Degree3

    CONNECTION DATA

    CONNECTION DATA
    Conductor Cross Section Stranded min.0.2 mm²
    Conductor Cross Section Stranded max.2.5 mm²
    Conductor Cross Section AWG/Kcmil min24 AWG
    Conductor Cross Section AWG/Kcmil max12 AWG
    Conductor Cross Section Stranded with Ferrule/Lug min0.2 mm²
    Conductor Cross Section Stranded with Ferrule/Lug max2.5 mm²
    2 Conductors with same Cross Section Stranded min0.2 mm²
    2 Conductor with same Cross Section Stranded max1.5 mm²
    Conductor Cross Section Solid min0.2 mm²
    Conductor Cross Section Solid max4 mm²
    Stripping Length8 mm

    DIMENSIONS

    DIMENSIONS
    Height with DIN 35 x 15 mm rail 68.5 mm
    Height with DIN 35 x 7.5 mm rail 61 mm
    Length 62 mm
    Width (Thickness)5 mm

    DIODE SPECIFICATIONS

    SURGE SUPRESSOR SPECIFICATIONS

    FUSE SPECIFICATIONS

    ORDERING INFORMATION

    ORDERING INFORMATION
    CAT. NO.DESCRIPTIONSTD. PACK
    ODL2.5A(I.S)2.5 sq.mm 2 Level Offset internally shorted stackable type Terminal Block in Grey colour50

    ACCESSORIES

    ACCESSORIES
    IMAGES
    CAT. NO. DESCRIPTION STD. PACK
    CA702
    CA702 End Clamp in Polyamide 66 suitable for Din 32 / Din 35 / Din 35-15 Rails 50
    CA202
    CA202 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 25
    CA509/K5
    CA509/K5 Blank Marking Tag 100
    SCS0.6/3.5AC
    SCS0.6/3.5 Electricians Screwdriver for slotted screws 10
    JX2.5/2
    JX2.5/2 Shorting Link for 2.5 sq mm series 100
    JX2.5/3 Shorting Link for 2.5 sq mm series 50
    JX2.5/4 Shorting Link for 2.5 sq mm series 50
    JX2.5/5 Shorting Link for 2.5 sq mm series 50
    JX2.5/6 Shorting Link for 2.5 sq mm series 50
    JX2.5/7 Shorting Link for 2.5 sq mm series 10
    JX2.5/8 Shorting Link for 2.5 sq mm series 10
    JX2.5/10 Shorting Link for 2.5 sq mm series 10
    EP1ODL2.5
    EP1ODL2.5 End Plate in Grey colour 50
    EPODL2.5
    EPODL2.5 End Plate in Grey colour 50

    NOTES

    Extra Information

    RATINGS AS PER STANDARDS

    STANDARDSIEC 60947-7-1UL 1059CSA C.22.2 No:158
    ApprovalsCEULCSA
    Conductor Cross Section Stranded min.0.2 mm²24 AWG24 AWG
    Conductor Cross Section Stranded max.2.5 mm²12 AWG12 AWG
    Rated Voltage 800 V300 V300 V
    Rated Current 24 A25 A25 A
    Tightening Torque 0.4 Nm4.5 lb-in4.5 lb-in

    APPROVALS

    APPROVALS